Technical
Data
Rated power of PMG Motors:
Type
|
Power (kW)
|
Mn (Nm)
|
3000
(min-1)
|
2500
(min-1)
|
2000
(min-1)
|
1500
(min-1)
|
1000
(min-1)
|
500
(min-1)
|
PMG 100S |
20
|
17
|
13
|
10
|
6,5
|
3,3
|
61
|
PMG 100M |
23
|
19
|
15
|
11
|
7,5
|
3,8
|
72
|
PMG 100L |
27
|
22
|
18
|
13
|
9
|
4,5
|
85
|
PMG 112S |
44
|
36
|
29
|
22
|
14,5
|
7,5
|
139
|
PMG 112M |
50
|
41
|
33
|
25
|
16,5
|
8,5
|
160
|
PMG 112L |
57
|
47
|
38
|
28
|
19
|
9,5
|
180
|
PMG 132S |
78
|
65
|
52
|
39
|
26
|
13
|
248
|
PMG 132M |
89
|
74
|
59
|
44
|
29
|
15
|
283
|
PMG 132L |
100
|
83
|
66
|
50
|
33
|
16,5
|
318
|
PMG 160S |
130
|
108
|
86
|
65
|
43
|
21,5
|
414
|
PMG 160M |
144
|
120
|
96
|
72
|
48
|
24
|
460
|
PMG 160L |
157
|
131
|
105
|
78
|
52
|
26
|
500
|
PMG 180S |
192
|
160
|
128
|
96
|
64
|
32
|
612
|
PMG 180M |
214
|
178
|
142
|
107
|
71
|
35,5
|
681
|
PMG 180L |
236
|
196
|
157
|
118
|
78
|
39
|
750
|
PMG 200S |
350
|
291
|
233
|
175
|
117
|
58
|
1000
|
PMG 200M |
378
|
315
|
252
|
189
|
126
|
63
|
1150
|
PMG 200L |
408
|
340
|
272
|
204
|
136
|
68
|
1300
|
PMG 225S |
436
|
363
|
290
|
218
|
145
|
72,5
|
1400
|
PMG 225M |
-
|
436
|
350
|
262
|
174
|
87
|
1700
|
PMG 225L |
-
|
523
|
418
|
314
|
210
|
105
|
2000
|
PMG 280S |
-
|
-
|
-
|
450
|
300
|
150
|
2800
|
PMG 280M |
-
|
-
|
-
|
500
|
334
|
167
|
3200
|
PMG 280L |
-
|
-
|
-
|
550
|
367
|
188
|
3500
|
Electro-Magnetical Compatability:
The Electro-Magnetical Compatability (EMC) requires on the one
hand, that the devices have no internal problems with interferences,
meaning they are not interference prone, and on the other hand,
that they don't go beyond a certain level of RMI Emission, which
means they still don't disturb other devices.
To reach these protective targets (defined in the EMC directive
(89/336/EEC)) with our PMG Drives, correct EMC measures must be
taken at design and at installation. For the inverter, a document
is available which describes the RMI Emission and will give help
to the user to determine the necessary measures for observance of
the given EMC directives.
After extensive tests and measurements it has been proven that
our component parts combined with correct installation, the given
limit values in standard EN 50082-2 (Interference immunity in the
area of industry) and standard EN 50081-2 (RFI Emission in the area
of industry) were not exceeded.
|